erl_ddll
Dynamic driver loader and linker.
This module provides an interface for loading and unloading Erlang linked-in drivers in runtime.
Note!
This is a large reference document. For casual use of this
module, and for most real world applications, the
descriptions of functions
load/2
and
unload/1
are enough to getting started.
The driver is to be provided as a dynamically linked library
in an object code format specific for the platform in use,
that is, .so
files on most Unix systems and .ddl
files on Windows. An Erlang linked-in driver must provide
specific interfaces to the emulator, so this module is not
designed for loading arbitrary dynamic libraries. For more
information about Erlang drivers, see
erts:erl_driver
.
When describing a set of functions (that is, a module, a part of a module, or an application), executing in a process and wanting to use a ddll-driver, we use the term user. A process can have many users (different modules needing the same driver) and many processes running the same code, making up many users of a driver.
In the basic scenario, each user loads the driver before starting to use it and unloads the driver when done. The reference counting keeps track of processes and the number of loads by each process. This way the driver is only unloaded when no one wants it (it has no user). The driver also keeps track of ports that are opened to it. This enables delay of unloading until all ports are closed, or killing of all ports that use the driver when it is unloaded.
The interface supports two basic scenarios of loading and unloading. Each scenario can also have the option of either killing ports when the driver is unloading, or waiting for the ports to close themselves. The scenarios are as follows:
This (most common) scenario simply supports that each user of the driver loads it when needed and unloads it when no longer needed. The driver is always reference counted and as long as a process keeping the driver loaded is still alive, the driver is present in the system.
Each user of the driver use literally the same pathname for the driver when demanding load, but the users are not concerned with if the driver is already loaded from the file system or if the object code must be loaded from file system.
The following two pairs of functions support this scenario:
When using the load/unload
interfaces, the
driver is not unloaded until the
last port using the driver is closed. Function
unload/1
can return immediately, as the
users
have no interrest in when the unloading occurs. The
driver is unloaded when no one needs it any longer.
If a process having the driver loaded dies, it has the same effect as if unloading is done.
When loading, function load/2
returns
ok
when any instance of the driver is
present. Thus, if a driver is waiting to get unloaded
(because of open ports), it simply changes state to no
longer need unloading.
These interfaces are intended to be used when it is considered an
error that ports are open to a driver that no
user
has loaded. The ports that are still open when the
last user calls
unload_driver/1
or when the last process having the
driver loaded dies, are killed with reason
driver_unloaded
.
The function names load_driver
and
unload_driver
are kept for backward
compatibility.
This scenario can occur if the driver code needs replacement during operation of the Erlang emulator. Implementing driver code replacement is a little more tedious than Beam code replacement, as one driver cannot be loaded as both "old" and "new" code. All users of a driver must have it closed (no open ports) before the old code can be unloaded and the new code can be loaded.
The unloading/loading is done as one atomic operation, blocking all processes in the system from using the driver in question while in progress.
The preferred way to do driver code replacement is to let one single process keep track of the driver. When the process starts, the driver is loaded. When replacement is required, the driver is reloaded. Unload is probably never done, or done when the process exits. If more than one user has a driver loaded when code replacement is demanded, the replacement cannot occur until the last "other" user has unloaded the driver.
Demanding reload when a reload is already in progress is always an error. Using the high-level functions, it is also an error to demand reloading when more than one user has the driver loaded.
To simplify driver replacement, avoid designing your system so that more than one user has the driver loaded.
The two functions for reloading drivers are to be used together with corresponding load functions to support the two different behaviors concerning open ports:
This pair of functions is used when reloading is to be done after the last open port to the driver is closed.
As reload/2
waits for the reloading to
occur, a misbehaving process keeping open ports to
the driver (or keeping the driver loaded) can cause
infinite waiting for reload. Time-outs must be provided
outside of the process demanding the reload or by using
the low-level interface
try_load/3
in combination with driver monitors.
This pair of functions are used when open ports to
the driver are to be killed with reason
driver_unloaded
to allow for new driver code to
get loaded.
However, if another process has the driver loaded,
calling reload_driver
returns error code
pending_process
. As stated earlier,
the recommended design is to not allow other
users than the "driver
reloader" to demand loading of the driver in question.
Functions
demonitor(MonitorRef) -> ok
MonitorRef = reference()
Removes a driver monitor in much the same way as
erlang:demonitor/1
in ERTS
does with process monitors. For details about how to create
driver monitors, see
monitor/2
,
try_load/3
, and
try_unload/2
.
The function throws a badarg
exception if the
parameter is not a reference()
.
format_error(ErrorDesc) -> string()
ErrorDesc = term()
Takes an
returned by load, unload, or
reload functions and returns a string that
describes the error or warning.
Note!
Because of peculiarities in the dynamic loading interfaces on different platforms, the returned string is only guaranteed to describe the correct error if format_error/1 is called in the same instance of the Erlang virtual machine as the error appeared in (meaning the same operating system process).
info() -> AllInfoList
AllInfoList = [DriverInfo]
DriverInfo = {DriverName, InfoList}
DriverName = string()
InfoList = [InfoItem]
InfoItem = {Tag :: atom(), Value :: term()}
Returns a list of tuples {
,
where
is the result of calling
info/1
for that
. Only dynamically linked-in drivers are
included in the list.
info(Name) -> InfoList
Name = driver()
InfoList = [InfoItem, ...]
InfoItem = {Tag :: atom(), Value :: term()}
Returns a list of tuples {
,
where
is the information item and
is the result of calling
info/2
with this driver
name and this tag. The result is a tuple list containing all information
available about a driver.
The following tags appears in the list:
processes
driver_options
port_count
linked_in_driver
permanent
awaiting_load
awaiting_unload
For a detailed description of each value, see
info/2
.
The function throws a badarg
exception if the driver
is not present in the system.
info(Name, Tag) -> Value
Name = driver()
Tag =
processes |
driver_options |
port_count |
linked_in_driver |
permanent |
awaiting_load |
awaiting_unloadValue = term()
Returns specific information about one aspect of a driver.
Parameter
specifies which aspect
to get information about. The return
differs
between different tags:
processes
Returns all processes containing
users of the specific drivers
as a list of tuples {pid(),integer() >= 0}
, where
integer()
denotes the number of users in process
pid()
.
driver_options
Returns a list of the driver options provided when
loading, and any options set by the driver
during initialization. The only valid option
is kill_ports
.
port_count
Returns the number of ports (an integer() >= 0
)
using the driver.
linked_in_driver
Returns a boolean()
, which is true
if the driver is a
statically linked-in one, otherwise false
.
permanent
Returns a boolean()
, which is true
if the driver has
made itself permanent (and is not a statically
linked-in driver), otherwise false
.
awaiting_load
Returns a list of all processes having monitors for
loading
active. Each process is returned as
{pid(),integer() >= 0}
, where integer()
is the
number of monitors held by process pid()
.
awaiting_unload
Returns a list of all processes having monitors for
unloading
active. Each process is returned as
{pid(),integer() >= 0}
, where integer()
is the
number of monitors held by process pid()
.
If option linked_in_driver
or permanent
returns true
, all other options return
linked_in_driver
or permanent
, respectively.
The function throws a badarg
exception if the driver
is not present in the system or if the tag is not supported.
load(Path, Name) -> ok | {error, ErrorDesc}
Loads and links the dynamic driver
.
is a file path to the directory containing the driver.
must be a sharable object/dynamic library. Two
drivers with different
parameters cannot be
loaded under the same name.
is a string or
atom containing at least one character.
The
specified is to correspond to the filename
of the dynamically loadable object file residing in
the directory specified as
, but without the
extension (that is, .so
). The driver name provided in
the driver initialization routine must correspond with the
filename, in much the same way as Erlang module names
correspond to the names of the .beam
files.
If the driver was previously unloaded, but is still
present because of open ports to it, a call to
load/2
stops the unloading and keeps the driver
(as long as
is the same), and ok
is
returned. If you really want the object code to be
reloaded, use reload/2
or the low-level interface
try_load/3
instead.
See also the description of
different scenarios
for
loading/unloading in the introduction.
If more than one process tries to load an already loaded
driver with the same
, or if the same process
tries to load it many times, the function returns
ok
. The emulator keeps track of the
load/2
calls, so that a corresponding number of
unload/2
calls must be done from the same
process before the driver gets unloaded. It is
therefore safe for an application to load a driver that is
shared between processes or applications when needed. It can
safely be unloaded without causing trouble for other
parts of the system.
It is not allowed to load multiple drivers with
the same name but with different Path
parameters.
Note!
is interpreted
literally, so that all loaders of the same driver must
specify the same literal
string,
although different paths can point out the same directory
in the file system (because of use of relative paths and
links).
On success, the function returns ok
. On
failure, the return value is {error,
,
where
is an opaque term to be
translated into human readable form by function
format_error/1
.
For more control over the error handling, use the
try_load/3
interface instead.
The function throws a badarg
exception if the
parameters are not specified as described here.
load_driver(Path, Name) -> ok | {error, ErrorDesc}
Works essentially as load/2
, but loads the driver
with other options. All ports using the
driver are killed with reason driver_unloaded
when the driver is to be unloaded.
The number of loads and unloads by different users influences the loading and unloading of a driver file. The port killing therefore only occurs when the last user unloads the driver, or when the last process having loaded the driver exits.
This interface (or at least the name of the functions) is
kept for backward compatibility.
Using try_load/3
with
{driver_options,[kill_ports]}
in the option list
gives the same effect regarding the port killing.
The function throws a badarg
exception if the
parameters are not specified as described here.
loaded_drivers() -> {ok, Drivers}
Drivers = [Driver]
Driver = string()
Returns a list of all the available drivers, both (statically) linked-in and dynamically loaded ones.
The driver names are returned as a list of strings rather than a list of atoms for historical reasons.
For more information about drivers, see
info
.
monitor(Tag, Item) -> MonitorRef
Tag = driver
Item = {Name, When}
Name = driver()
When = loaded | unloaded | unloaded_only
MonitorRef = reference()
Creates a driver monitor and works in many
ways as
erlang:monitor/2
in ERTS
,
does for processes. When a driver changes state, the monitor
results in a monitor message that is sent to the calling
process.
returned by this function is
included in the message sent.
As with process monitors, each driver monitor set only
generates one single message. The monitor is
"destroyed" after the message is sent, so it is then not
needed to call
demonitor/1
.
can also be used in subsequent calls
to demonitor/1
to
remove a monitor.
The function accepts the following parameters:
Tag
The monitor tag is always driver
, as this function
can only be used to create driver monitors. In the future,
driver monitors will be integrated with process monitors,
why this parameter has to be specified for consistence.
Item
Parameter
specifies
which driver to monitor (the driver name) and
which state change to monitor. The parameter
is a tuple of arity two whose first element is the
driver name and second element is one of the following:
loaded
Notifies when the driver is reloaded (or loaded if
loading is underway). It only makes sense to monitor
drivers that are in the process of being loaded or
reloaded. A future driver name for loading cannot be
monitored. That only results in a
DOWN
message sent immediately.
Monitoring for loading is therefore most useful when
triggered by function
try_load/3
,
where the monitor is created because the
driver is in such a pending state.
Setting a driver monitor for loading
eventually leads to one of the following messages
being sent:
{'UP', reference(), driver, Name, loaded}
This message is sent either immediately if the driver is already loaded and no reloading is pending, or when reloading is executed if reloading is pending.
The user is expected to know if reloading is demanded before creating a monitor for loading.
{'UP', reference(), driver, Name, permanent}
This message is sent if reloading was expected, but the (old) driver made itself permanent before reloading. It is also sent if the driver was permanent or statically linked-in when trying to create the monitor.
{'DOWN', reference(), driver, Name, load_cancelled}
This message arrives if reloading was
underway, but the requesting
user
cancelled it by dying or calling
try_unload/2
(or unload/1
/unload_driver/1
)
again before it was reloaded.
{'DOWN', reference(), driver, Name, {load_failure, Failure}}
This message arrives if reloading was
underway but the loading for some reason
failed. The Failure
term is one of the
errors that can be returned from
try_load/3
.
The error term can be passed to
format_error/1
for translation into human readable form. Notice
that the translation must be done in the same
running Erlang virtual machine as the error
was detected in.
unloaded
Monitors when a driver gets unloaded. If one monitors a driver that is not present in the system, one immediately gets notified that the driver got unloaded. There is no guarantee that the driver was ever loaded.
A driver monitor for unload eventually results in one of the following messages being sent:
{'DOWN', reference(), driver, Name, unloaded}
The monitored driver instance is now
unloaded. As the unload can be a result of a
reload/2
request, the driver can once
again have been loaded when this message
arrives.
{'UP', reference(), driver, Name, unload_cancelled}
This message is sent if unloading was expected, but while the driver was waiting for all ports to get closed, a new user of the driver appeared, and the unloading was cancelled.
This message appears if {ok, pending_driver}
was returned from
try_unload/2
for the last user
of the driver, and then {ok, already_loaded}
is returned
from a call to
try_load/3
.
If one really wants to monitor when the
driver gets unloaded, this message distorts
the picture, because no unloading was done.
Option unloaded_only
creates a monitor
similar to an unloaded
monitor, but
never results in this message.
{'UP', reference(), driver, Name, permanent}
This message is sent if unloading was expected, but the driver made itself permanent before unloading. It is also sent if trying to monitor a permanent or statically linked-in driver.
unloaded_only
A monitor created as unloaded_only
behaves
exactly as one created as unloaded
except that the
{'UP', reference(), driver, Name, unload_cancelled}
message is never sent, but the monitor instead persists until
the driver really gets unloaded.
The function throws a badarg
exception if the
parameters are not specified as described here.
reload(Path, Name) -> ok | {error, ErrorDesc}
Reloads the driver named
from a possibly
different
than previously used. This
function is used in the code change
scenario
described in the
introduction.
If there are other users
of this driver, the function returns {error, pending_process}
,
but if there are no other users, the function call hangs until all
open ports are closed.
Note!
Avoid mixing multiple users with driver reload requests.
To avoid hanging on open ports, use function
try_load/3
instead.
The
and
parameters
have exactly the same meaning as when calling the plain function
load/2
.
On success, the function returns ok
. On
failure, the function returns an opaque error,
except the pending_process
error described
earlier. The opaque errors are to be translated into human
readable form by function
format_error/1
.
For more control over the error handling, use the
try_load/3
interface instead.
The function throws a badarg
exception if the
parameters are not specified as described here.
reload_driver(Path, Name) -> ok | {error, ErrorDesc}
Works exactly as reload/2
,
but for drivers loaded with the
load_driver/2
interface.
As this interface implies that ports are killed when the last user disappears, the function does not hang waiting for ports to get closed.
For more details, see
scenarios
in this module
description and the function description for
reload/2
.
The function throws a badarg
exception if the
parameters are not specified as described here.
try_load(Path, Name, OptionList) ->
{ok, Status} |
{ok, PendingStatus, Ref} |
{error, ErrorDesc}
Path = path()
Name = driver()
OptionList = [Option]
Option =
{driver_options, DriverOptionList} |
{monitor, MonitorOption} |
{reload, ReloadOption}DriverOptionList = [DriverOption]
DriverOption = kill_ports
MonitorOption = ReloadOption = pending_driver | pending
Status = loaded | already_loaded | PendingStatus
PendingStatus = pending_driver | pending_process
Ref = reference()
ErrorDesc = ErrorAtom | OpaqueError
ErrorAtom =
linked_in_driver |
inconsistent |
permanent |
not_loaded_by_this_process |
not_loaded |
pending_reload |
pending_processOpaqueError = term()
Provides more control than the
load/2
/reload/2
and
load_driver/2
/reload_driver/2
interfaces. It
never waits for completion of other operations related
to the driver, but immediately returns the status of the
driver as one of the following:
{ok, loaded}
The driver was loaded and is immediately usable.
{ok, already_loaded}
The driver was already loaded by another process
or is in use by a living port, or both. The load by you is
registered and a corresponding try_unload
is
expected sometime in the future.
{ok, pending_driver}
or {ok, pending_driver, reference()}
The load request is registered, but the loading is
delayed because an earlier instance of the
driver is still waiting to get unloaded (open
ports use it). Still, unload is expected when you are
done with the driver. This return value
mostly occurs when options
{reload,pending_driver}
or
{reload,pending}
are used, but
can occur when another
user is unloading a
driver in parallel and driver option kill_ports
is set.
In other words, this return value always needs
to be handled.
{ok, pending_process}
or {ok, pending_process, reference()}
The load request is registered, but the loading is
delayed because an earlier instance of the
driver is still waiting to get unloaded by another
user (not only by a
port, in which case {ok,pending_driver}
would
have been returned). Still, unload is expected when you
are done with the driver. This return value
only occurs when option {reload,pending}
is used.
When the function returns {ok, pending_driver}
or
{ok, pending_process}
, one can get information
about when the driver is actually loaded by using
option {monitor,
.
When monitoring is requested, and a corresponding
{ok, pending_driver}
or {ok, pending_process}
would
be returned, the function instead returns a tuple
{ok,
and the process then gets a monitor message later, when the
driver gets loaded. The monitor message to expect is described in
the function description of
monitor/2
.
Note!
In case of loading, monitoring can not only get
triggered by using option {reload,
,
but also in special cases where the load error is transient. Thus,
{monitor, pending_driver}
is to be used under basically
all real world circumstances.
The function accepts the following parameters:
Path
The file system path to the directory where the driver
object file is located. The filename of the object file
(minus extension) must correspond to the driver name
(used in parameter
) and the driver must
identify itself with the same name.
can be provided as an iolist(),
meaning it can be a list of other iolist()
s, characters
(8-bit integers), or binaries, all to be flattened
into a sequence of characters.
The (possibly flattened)
parameter must be
consistent throughout the system. A driver is to, by
all users, be loaded
using the same literal
.
The exception is when reloading is requested,
in which case
can be specified
differently. Notice that all
users trying to load the
driver later need to use the
new
if
is changed using a reload
option. This is yet another reason
to have only one loader of a driver one wants to
upgrade in a running system.
Name
This parameter is the name of the driver
to be used in subsequent calls to function
erlang:open_port
in ERTS
.
The name can be specified as an iolist()
or
an atom()
. The name specified when loading is used
to find the object file (with the help of
and the system-implied extension suffix, that is, .so
).
The name by which the driver identifies itself must also be consistent
with this
parameter, much as
the module name of a Beam file much corresponds to its filename.
OptionList
Some options can be specified to control the loading operation. The options are specified as a list of two-tuples. The tuples have the following values and meanings:
{driver_options, DriverOptionList }
This is to provide options that changes its general behavior and "sticks" to the driver throughout its lifespan.
The driver options for a specified driver name need always to be consistent, even when the driver is reloaded, meaning that they are as much a part of the driver as the name.
The only allowed driver option is
kill_ports
, which means that all ports opened
to the driver are killed with exit reason
driver_unloaded
when no process any longer
has the driver loaded. This situation arises either
when the last user calls
try_unload/2
, or
when the last process having loaded the driver exits.
{monitor, MonitorOption }
A
tells try_load/3
to
trigger a driver monitor under certain
conditions. When the monitor is triggered, the
function returns a three-tuple
{ok,
, where
reference()
is the monitor reference for the driver monitor.
Only one
can be specified.
It is one of the following:
-
The atom
pending
, which means that a monitor is to be created whenever a load operation is delayed, -
The atom
pending_driver
, in which a monitor is created whenever the operation is delayed because of open ports to an otherwise unused driver.
Option pending_driver
is of little use, but
is present for completeness, as it is well defined which
reload options that can give rise to which delays.
However, it can be a good idea to use the same
as the
, if present.
If reloading is not requested, it can still be
useful to specify option monitor
, as
forced unloads (driver option kill_ports
or
option kill_ports
to
try_unload/2
)
trigger a transient state where driver loading
cannot be performed until all closing ports are
closed. Thus, as try_unload
can, in
almost all situations, return {ok, pending_driver}
,
always specify at least {monitor, pending_driver}
in production code (see the monitor discussion earlier).
{reload, ReloadOption }
This option is used to
reload a driver from disk, most often in a
code upgrade scenario. Having a reload
option
also implies that parameter
does
not need to be consistent with earlier loads of
the driver.
To reload a driver, the process must have loaded the driver before, that is, there must be an active user of the driver in the process.
The reload
option can be either of the following:
pending
With the atom pending
, reloading is requested
for any driver and is effectuated when all
ports opened to the driver are closed. The driver
replacement in this case takes
place regardless if there are still
pending users
having the driver loaded.
The option also triggers port-killing (if driver
option kill_ports
is used) although
there are pending users, making it usable for forced
driver replacement, but laying much
responsibility on the driver
users.
The pending option is seldom used as one does not want other
users to have loaded
the driver when code change is underway.
pending_driver
This option is more useful. Here, reloading is queued
if the driver is not loaded by any other
users, but the
driver has opened ports, in which case
{ok, pending_driver}
is returned
(a monitor
option is recommended).
If the driver is unloaded (not present in the system),
error code not_loaded
is returned. Option
reload
is intended for when the user
has already loaded the driver in advance.
The function can return numerous errors, some can only be returned given a certain combination of options.
Some errors are opaque and can only be interpreted by
passing them to function
format_error/1
,
but some can be interpreted directly:
{error,linked_in_driver}
The driver with the specified name is an Erlang statically linked-in driver, which cannot be manipulated with this API.
{error,inconsistent}
The driver is already loaded with other
or a different
literal Path
argument.
This can occur even if a reload
option is specified,
if DriverOptionList
differs from the current.
{error, permanent}
The driver has requested itself to be permanent, making it behave like an Erlang linked-in driver and can no longer be manipulated with this API.
{error, pending_process}
The driver is loaded by other
users when
option {reload, pending_driver}
was specified.
{error, pending_reload}
Driver reload is already requested by another
user when option
{reload,
was specified.
{error, not_loaded_by_this_process}
Appears when option reload
is specified. The
driver
is present in the system, but there
is no user of it in this
process.
{error, not_loaded}
Appears when option reload
is specified. The
driver
is not in the system. Only drivers
loaded by this process can be reloaded.
All other error codes are to be translated by function
format_error/1
.
Notice that calls to format_error
are to be
performed from the same running instance of the Erlang
virtual machine as the error is detected in, because of
system-dependent behavior concerning error values.
If the arguments or options are malformed, the function
throws a badarg
exception.
try_unload(Name, OptionList) ->
{ok, Status} |
{ok, PendingStatus, Ref} |
{error, ErrorAtom}
Name = driver()
OptionList = [Option]
Option = {monitor, MonitorOption} | kill_ports
MonitorOption = pending_driver | pending
Status = unloaded | PendingStatus
PendingStatus = pending_driver | pending_process
Ref = reference()
ErrorAtom =
linked_in_driver |
not_loaded |
not_loaded_by_this_process |
permanent
This is the low-level function to unload (or decrement
reference counts of) a driver. It can be used to force port
killing, in much the same way as the driver option
kill_ports
implicitly does. Also, it can trigger a
monitor either because other
users still have the driver
loaded or because open ports use the driver.
Unloading can be described as the process of telling the emulator that this particular part of the code in this particular process (that is, this user) no longer needs the driver. That can, if there are no other users, trigger unloading of the driver, in which case the driver name disappears from the system and (if possible) the memory occupied by the driver executable code is reclaimed.
If the driver has option kill_ports
set, or if
kill_ports
is specified as an option to this
function, all pending ports using this driver are
killed when unloading is done by the last
user. If no port-killing
is involved and there are open ports, the unloading
is delayed until no more open ports use the
driver. If, in this case, another
user (or even this user)
loads the driver again before the driver is unloaded, the
unloading never takes place.
To allow the user to
request unloading to wait for actual unloading,
monitor
triggers can be specified in much the same way as
when loading. However, as users
of this function seldom are interested in more than decrementing the
reference counts, monitoring is seldom needed.
Note!
If option kill_ports
is used, monitor trigging is crucial,
as the ports are not guaranteed to be killed until the driver is unloaded.
Thus, a monitor must be triggered for at least the pending_driver
case.
The possible monitor messages to expect are the
same as when using option unloaded
to function
monitor/2
.
The function returns one of the following statuses upon success:
{ok, unloaded}
The driver was immediately unloaded, meaning that the driver name is now free to use by other drivers and, if the underlying OS permits it, the memory occupied by the driver object code is now reclaimed.
The driver can only be unloaded when there are no open ports using it and no more users require it to be loaded.
{ok, pending_driver}
or
{ok, pending_driver, reference()}
Indicates that this call removed the last user from the driver, but there are still open ports using it. When all ports are closed and no new users have arrived, the driver is reloaded and the name and memory reclaimed.
This return value is valid even if option kill_ports
was used, as killing ports can be a process that does not
complete immediately. However, the condition is in that case
transient. Monitors are always useful to detect when the driver
is really unloaded.
{ok, pending_process}
or
{ok, pending_process, reference()}
The unload request is registered, but
other users still hold
the driver. Notice that the term pending_process
can refer to the running process; there can be more
than one user in the
same process.
This is a normal, healthy, return value if the call was
just placed to inform the emulator that you have no
further use of the driver. It is the most
common return value in the most common
scenario
described in the introduction.
The function accepts the following parameters:
Name
is the name of the
driver to be unloaded. The name can be specified as an
iolist()
or as an atom()
.
OptionList
Argument
can be used to specify
certain behavior regarding ports and triggering
monitors under certain conditions:
kill_ports
Forces killing of all ports opened using this driver,
with exit reason driver_unloaded
, if you are
the last user
of the driver.
If other users have the driver loaded, this option has no effect.
To get the consistent behavior of killing ports
when the last user
unloads, use driver option
kill_ports
when loading the driver instead.
{monitor, MonitorOption }
Creates a driver monitor if the condition
specified in
is true. The valid
options are:
pending_driver
Creates a driver monitor if the return value is to
be {ok, pending_driver}
.
pending
Creates a monitor if the return value is
{ok, pending_driver}
or {ok, pending_process}
.
The pending_driver
is
by far the most useful. It must be used to ensure that the
driver really is unloaded and the ports closed
whenever option kill_ports
is used, or the
driver can have been loaded with driver option
kill_ports
.
Using the monitor triggers in the call to
try_unload
ensures that the monitor is
added before the unloading is executed, meaning
that the monitor is always properly triggered,
which is not the case if monitor/2
is called
separately.
The function can return the following error conditions, all well specified (no opaque values):
{error, linked_in_driver}
You were trying to unload an Erlang statically linked-in driver, which cannot be manipulated with this interface (and cannot be unloaded at all).
{error, not_loaded}
The driver
is not present in the system.
{error, not_loaded_by_this_process}
The driver
is present in the system, but
there is no user of
it in this process.
As a special case, drivers can be unloaded from
processes that have done no corresponding call to
try_load/3
if, and only if, there are
no users of the driver at all, which can occur if the
process containing the last user dies.
{error, permanent}
The driver has made itself permanent, in which case it can no longer be manipulated by this interface (much like a statically linked-in driver).
The function throws a badarg
exception if the
parameters are not specified as described here.
unload(Name) -> ok | {error, ErrorDesc}
Name = driver()
ErrorDesc = term()
Unloads, or at least dereferences the driver named
. If the caller is the last
user of the driver,
and no more open ports use the driver, the driver
gets unloaded. Otherwise, unloading
is delayed until all ports are closed and no
users remain.
If there are other users
of the driver, the reference counts of the driver is merely decreased,
so that the caller is no longer considered a
user of the driver. For use
scenarios, see the description
in the beginning of this module.
The
returned is an opaque value to be
passed further on to function
format_error/1
.
For more control over the operation, use the
try_unload/2
interface.
The function throws a badarg
exception if the
parameters are not specified as described here.
unload_driver(Name) -> ok | {error, ErrorDesc}
Name = driver()
ErrorDesc = term()
Unloads, or at least dereferences the driver named
. If the caller is the last
user of the driver, all
remaining open ports using the driver are killed with
reason driver_unloaded
and the driver
eventually gets unloaded.
If there are other users
of the driver, the reference counts of the driver is merely
decreased, so that the caller is no longer considered a
user. For
use scenarios, see the
description
in the
beginning of this module.
The
returned is an opaque value to be
passed further on to function
format_error/1
.
For more control over the operation, use the
try_unload/2
interface.
The function throws a badarg
exception if the
parameters are not specified as described here.